About storage tank insulation system and cold insulation material performance

About storage tank insulation system and cold insulation material performance

  • Categories:Doer Classroom
  • Author:
  • Origin:
  • Time of issue:2020-11-06
  • Views:0

(Summary description)Anchor devices are evenly arranged around the lower part of the main container and the secondary container, the main container has 72 pieces, and the secondary container has 104 pieces, and they are reliably connected with the foundation embedded anchoring device, so that the main container and the secondary container are fastened to the base platform of the storage tank. Above, to prevent the equipment from tilting and lifting under the action of working load and external force (such as wind load, seismic load, etc.).

About storage tank insulation system and cold insulation material performance

(Summary description)Anchor devices are evenly arranged around the lower part of the main container and the secondary container, the main container has 72 pieces, and the secondary container has 104 pieces, and they are reliably connected with the foundation embedded anchoring device, so that the main container and the secondary container are fastened to the base platform of the storage tank. Above, to prevent the equipment from tilting and lifting under the action of working load and external force (such as wind load, seismic load, etc.).

  • Categories:Doer Classroom
  • Author:
  • Origin:
  • Time of issue:2020-11-06
  • Views:0
Information

  Anchor devices are evenly arranged around the lower part of the main container and the secondary container, the main container has 72 pieces, and the secondary container has 104 pieces, and they are reliably connected with the foundation embedded anchoring device, so that the main container and the secondary container are fastened to the base platform of the storage tank. Above, to prevent the equipment from tilting and lifting under the action of working load and external force (such as wind load, seismic load, etc.).

  When the anchoring device of the main vessel passes through the thermal angle protective bottom plate, a flat sleeve + sealing plate combination structure is adopted to minimize the stress transferred to the thermal angle protective layer bottom plate through the anchoring device.

  A, bottom insulation layer. The ZES-8O0 foam glass brick is laid between the bottom plate of the main container and the bottom plate of the secondary container as the bottom insulation layer and bears the weight of the main container and the medium, and the pearl sand reinforced concrete ring beam is used in the pressure-bearing annular area directly under the main container wall (The steel bar is required to be stainless steel) to distribute the load, and the lower part of the concrete ring beam uses ZES-1200 high-density foam glass bricks. The insulation layer at the bottom of the storage tank is as follows from top to bottom: the main container bottom plate (edge ​​plate + medium plate)-C45 concrete leveling layer-pearl sand concrete ring beam, ZES-SO0 foam glass brick (same layer)-C45 concrete leveling layer- Thermal corner protective layer bottom plate-C45 concrete leveling layer-ZES1200 foam glass brick, ZES-8O0 foam glass brick (same layer)-C45 concrete leveling layer-secondary container bottom plate.

  B, thermal corner protection insulation layer. The 150mm ring-shaped space between the wall panel of the secondary container cylinder and the thermal corner protection cylinder is built with ZES8O0 foam glass bricks as cold insulation materials and supports to isolate the cold transfer occurring in the direction of the sidewall of the storage tank. Low temperature glue is applied between the foam glass brick layer and the layer of the thermal corner protection thermal insulation layer as a bonding agent, and the upper sealing ring plate of the thermal corner protective thermal insulation layer is filled with glass fiber wool with a thickness of 50mm after compression.

  Insulating layer in the direction of the side wall of the main container cylinder. The outer wall of the main container is provided with a complete circle of combined flexible elastic layer (from the inside to the outside: cotton cloth, elastic cotton, cotton cloth, and glass cloth), which is used to buffer the side pressure of pearl sand, and the annular space between the main container and the secondary container is densely filled. The pearlescent sand is used to isolate the transfer of cold energy in the direction of the side wall of the main container.

  Lay 10 layers of glass fiber wool on the suspended ceiling. The thickness of the single layer of glass fiber cotton shall not be less than 100mm. The total thickness after laying is within the range of 800mm-1000mm to keep the top of the main container with good thermal insulation performance.

  Durr equipment is now available

  3-250 cubic liquid argon vacuum storage tank

  200-3000 cubic atmospheric cryogenic liquid argon storage tank

什么是液氩-杜尔装备

什么是液氩-杜尔装备

什么是液氩-杜尔装备

Scan the QR code to read on your phone

Latest Recommended

Analysis of LNG storage tanks!

Analysis of LNG storage tanks!

Nanyang Duer Gas Equipment Co., Ltd. is a joint-stock high-tech enterprise. The company is mainly engaged in the research and development, design, manufacture and after-sales service of various industrial gas equipment and cryogenic equipment. The company's products mainly include LNG cryogenic storage tanks, LNG storage tanks, water bath vaporizers, LNG full-capacity tanks, LNG vaporization stations, LNG liquid vacuum storage tanks, LNG storage tanks, large atmospheric LNG storage tanks, large LNG storage tanks, vacuum cryogenic storage Tanks, LNG storage tanks, large cryogenic tanks, natural gas vacuum storage tanks, cryogenic storage tanks, etc.
What are the special points in the design of large LNG storage tanks?

What are the special points in the design of large LNG storage tanks?

Generally, LNG is stored at -162 degrees. In order to ensure large-scale LNG storage tanks, the following factors need to be considered when selecting the metal materials for manufacturing cryogenic storage tanks: the strength within the range of normal temperature to -196 degrees, and sufficient in the use temperature range Toughness and plasticity, so as not to cause brittle failure. Stable metallographic structure, good processability and weldability, low price, easy to buy.
Public announcement of basic information of Nanyang Dur Gas Equipment Co., Ltd.

Public announcement of basic information of Nanyang Dur Gas Equipment Co., Ltd.

On May 26, 2021, Nanyang Municipal Bureau of Ecology and Environment issued the “Notice on Announcement of the List of Key Enterprises in Nanyang’s Compulsory Cleaner Production Audit for 2021” Wanhuan Office [2021] No. 20, Nanyang Duer Gas Equipment Co., Ltd. was It is included in this batch of mandatory cleaner production audit list, according to the "Clean Production Audit Measures"
Process analysis of LNG vaporization station!

Process analysis of LNG vaporization station!

Process flow of LNG vaporization station. The LNG transported by the tanker is turned on at the unloading platform of the gasification station to pressurize the tanker with its own booster. The pressure difference between the LNG tanker and the storage tank in the station is formed, which plays a role in the pressure difference. Next, the LNG is fed into the low-temperature storage tank of the gasification station for storage through the unloading hose. The low-temperature storage tank in the station makes the pressure of the storage tank reach the value through the storage tank booster, and the LNG in the tank enters the LNG vaporizer through the liquid outlet pipe.
Previous page
1
2
12
南阳杜尔气体装备有限公司

Nanyang Duer Gas Equipment Co., Ltd. is a joint-stock high-tech enterprise. The company is located in the picturesque north of the Han River and south of Funiu; the source of the South-to-North Water Diversion-Nanyang, the land of......

Contact us

Address:

South Section of Jingyi Road, Industrial Cluster District, Sheqi County, Nanyang City, Henan Province

Phone:

189-3780-9909

Mail:

nyduer@163.com

Quick Links

Follow us

南阳杜尔气体装备有限公司

Copyright ©2020 Nanyang Doer Gaseous Equipment Co., Ltd     豫ICP备15028160号-53     Powered by: www.300.cn  luoyang