Propane full tank spray cooling device-Dürr equipment
- Categories:Industry Information
- Author:
- Origin:
- Time of issue:2021-04-22
- Views:0
(Summary description)The propane storage tank is equipped with a spray cooling fire-fighting device, which is composed of pipelines, nozzles and water supply risers. It is installed on the tank roof, tank wall, stairs, safety passages and important process instruments and equipment, and the system installation complies with relevant domestic regulations.
Propane full tank spray cooling device-Dürr equipment
(Summary description)The propane storage tank is equipped with a spray cooling fire-fighting device, which is composed of pipelines, nozzles and water supply risers. It is installed on the tank roof, tank wall, stairs, safety passages and important process instruments and equipment, and the system installation complies with relevant domestic regulations.
- Categories:Industry Information
- Author:
- Origin:
- Time of issue:2021-04-22
- Views:0
The propane storage tank is equipped with a spray cooling fire-fighting device, which is composed of pipelines, nozzles and water supply risers. It is installed on the tank roof, tank wall, stairs, safety passages and important process instruments and equipment, and the system installation complies with relevant domestic regulations.
The fire-fighting sprinkler pipeline of the storage tank is made of 20# seamless double-sided galvanized steel pipe, and the device adopts the overall anti-corrosion method. The device is prefabricated and welded and then integrally pickled and hot-dip galvanized inside and outside.
The arrangement of the nozzles is arranged so that the fan-shaped water curtain sprayed by it has a certain intersection on the tank wall to prevent blind spots;
There is a pressure reducing facility at the main entrance of the sprinkler device to control the inlet pressure. The outlet pressure and outflow coefficient of the sprinkler and the piping conditions meet the requirement that the actual spray volume after installation cannot exceed 5% of the calculated water volume; the spray intensity is as per The top of the tank is not less than 4L/min.㎡, and the wall of the tank is not less than 2.5L/min.㎡.
Scan the QR code to read on your phone
Latest Recommended
Analysis of LNG storage tanks!
What are the special points in the design of large LNG storage tanks?
Public announcement of basic information of Nanyang Dur Gas Equipment Co., Ltd.
Process analysis of LNG vaporization station!
Nanyang Duer Gas Equipment Co., Ltd. is a joint-stock high-tech enterprise. The company is located in the picturesque north of the Han River and south of Funiu; the source of the South-to-North Water Diversion-Nanyang, the land of......
Contact us
Address:
South Section of Jingyi Road, Industrial Cluster District, Sheqi County, Nanyang City, Henan Province
Phone:
Mail:
Main products
Follow us
Copyright ©2020 Nanyang Doer Gaseous Equipment Co., Ltd 豫ICP备15028160号-53 Powered by: www.300.cn luoyang